Avaliação da manutenção da pre-carga de parafusos de ouro e titanio em proteses implanto-suportadas
Leonardo Henrique Vadenal Panza
DISSERTAÇÃO
Português
(Broch.)
T/UNICAMP P196a
[Pre-load maintenance in abutment and prosthetic screws implant restoration after simulated load cycling: an in vitro study]
Piracicaba, SP : [s.n.], 2006.
24f. : il.
Orientador: Altair Antoninha Del Bel Cury
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Resumo: O sucesso da terapia reabilitadora com implantes requer um equilíbrio entre fatores biológicos e mecânicos. Os fatores biológicos são multifatoriais, já os mecânicos associam-se à instabilidade da conexão implante-parafuso-intermediário. Entre os fatores responsáveis pela manutenção da...
Ver mais
Resumo: O sucesso da terapia reabilitadora com implantes requer um equilíbrio entre fatores biológicos e mecânicos. Os fatores biológicos são multifatoriais, já os mecânicos associam-se à instabilidade da conexão implante-parafuso-intermediário. Entre os fatores responsáveis pela manutenção da estabilidade desta conexão, a manutenção da pré-carga do parafuso é o mais importante. Com base nestas informações, este estudo buscou avaliar a manutenção da pré-carga de parafusos de ouro, após a aplicação de carga simulada, por meio da realização de ciclagem mecânica do conjunto protético, e também observar a ocorrência de rotação da coroa ou do intermediário protético em relação aos implantes. Para tanto, foram utilizados 40 implantes, 20 com hexágono interno e 20 externo, conectados a intermediários protéticos do tipo Esteticone com angulação de 17° e sem angulação, todos retidos por parafusos de titânio rosqueados a 20N/cm, sobre os quais foram parafusadas coroas confeccionadas em resina acrílica simulando pré-molares superiores humanos com parafusos de ouro apertados a 10N/cm. Cada conjunto foi então submetido ao ensaio de fadiga com aplicação de forças médias de 115 N no sentido do longo eixo do implante por 0.2 s, com uma freqüência de 1 Hz, totalizando um total de 250.000 de ciclos (correspondendo aproximadamente a 3 meses de uso). A manutenção da pré-carga dos parafusos, foi avaliada pelo destorque dos parafusos, após a realização do ensaio de fadiga, com a utilização de um torquímetro digital. Os resultados foram então submetidos à análise de variância a 2 critérios e ao teste de Tuckey, através dos quais foi possível observar que, para o parafuso protético, ocorreu diferença estatisticamente significante entre os tipos de implante, mas sem interação com o tipo de intermediário. No entanto para o parafuso do intermediário ocorreu diferença significativa tanto para o tipo de implante como entre os intermediários, com interação entre os fatores. A análise estatística apontou um desempenho melhor para a manutenção da pré-carga inicial dos parafusos, nos intermediários angulados tanto nos implantes de hexágono interno, quanto nos de hexágono externo. Nenhum dos corpos de prova apresentou rotação de coroa ou intermediário protético quando analisados ao microscópio
Ver menos
Abstract: After osseointegration failures, screw loosening is the most common problem in implant dentistry. However, controversies still exist regarding to the influence of type connection implant to abutment in screw loosing or fracture. This study evaluated pre-tightening maintenance in abutment...
Ver mais
Abstract: After osseointegration failures, screw loosening is the most common problem in implant dentistry. However, controversies still exist regarding to the influence of type connection implant to abutment in screw loosing or fracture. This study evaluated pre-tightening maintenance in abutment and prosthetic screws of external and internal implant hexagon with standard and 17° angulated abutments after fatigue testing. Also, the rotational dislodgement was checked using digital measurement microscope. Four subsets (n=10) of implants and abutments were assessed: (G1) internally hexed implant and standard abutment (G2) internally hexed implant and 17° angulated abutment (G3) externally hexed implant and standard abutments (G4) externally hexed implant and 17° angulated abutment. Abutments were retained by titanium screws tightened to 20 N/cm. Acrylic resin crowns were manufactured and were retained over the abutments with gold screws tightened at 10 N/cm, using an electronic torque controller. A vertical line was ascribed across the implant-abutment and crown-abutment interface to identify any rotational displacement. The fatigue tests were performed in a servo-hydraulic machine which delivered forces between 100 and 120 N for 250,000 cycles, through a piston to the crown. The implant-abutment interface were evaluated using a light microscope. Then, screw was removed and detorque value was recorded. Data were statistically analyzed using ANOVA and Tukey test (a=.05) No horizontal displacement of acrylic resin crown and abutments were observed. ANOVA showed significant difference for prosthetic screw between implant types, but without interaction with abutment. However, for abutment screw, there was a significant difference between implant type and abutment. Also, it was observed interaction between implant and abutments types. Internally hexed implants (G1 and G2) and externally hexed implants (G3 and G4) showed significant difference with a better performance for angulated abutment in comparison to standard abutment. Within the limitations of this study it was concluded that pre-tightening maintenance of screw was affected by the type of abutment and the type connection implant used. There was no dislodgement for crown or abutment when standard or pre-angulated abutments were used after 250.000 cycles of simulated loading. Indeed, internal and external hexed connections were effective to avoid rotation of crowns
Ver menos
Del Bel Cury, Altair Antoninha, 1948-
Orientador
Ferreira, Paulo Martins
Avaliador
Nóbilo, Mauro Antonio de Arruda, 1965-
Avaliador
Avaliação da manutenção da pre-carga de parafusos de ouro e titanio em proteses implanto-suportadas
Leonardo Henrique Vadenal Panza
Avaliação da manutenção da pre-carga de parafusos de ouro e titanio em proteses implanto-suportadas
Leonardo Henrique Vadenal Panza
Exemplares
Nº de exemplares: 1
Não existem reservas para esta obra