Effect of accelerated stability on the physical, chemical, and mechanical properties of experimental bleaching gels containing different bioadhesive polymers
Danielle Ferreira Sobral-Souza, Thayla Hellen Nunes Gouveia, André Luís Condeles, José Carlos Toledo Junior, Bruno Vilela Muniz, Michelle Franz-Montan, Maria Cibelle Pauli, Gislaine Ricci Leonardi, Débora Alves Nunes Leite Lima
ARTIGO
Inglês
Agradecimentos: The authors would like to thank Drogal manipulations and FGM-Dental products for the donation of their bleaching products. This study was partially supported by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brazil (CAPES)-Finance code 001
Abstract: To evaluate the physical–chemical (weight, pH, quantification of hydrogen peroxide) and mechanical (texture profile and rheology tests) properties of the experimental bleaching gel based on the bioadhesive polymer Aristoflex® AVC, after accelerated stability testing. A total of 300...
Ver mais
Abstract: To evaluate the physical–chemical (weight, pH, quantification of hydrogen peroxide) and mechanical (texture profile and rheology tests) properties of the experimental bleaching gel based on the bioadhesive polymer Aristoflex® AVC, after accelerated stability testing. A total of 300 syringes of bleaching gels were divided into 5 groups (n = 60): Whiteness Perfect® 10%-FGM (WP); carbamide peroxide 10% with aristoflex (CPa); carbamide peroxide 10% with Carbopol (CPc); aristoflex thickener (A); and Carbopol thickener (C). According to the following requirements and time, the accelerated stability test was performed: in an incubator at 40 °C and 75% humidity per 1, 3, and 6 months, and baseline (refrigerator at 5 °C and 25% humidity). The variables were analyzed following the statistical tests: Two-way ANOVA and Tukey’s test were applied to pH; weight data were analyzed using a mixed model for repeated measurements over time and the Tukey–Kramer test; one-way ANOVA and Tukey’s test analyzed the rheology test; generalized linear models were used to quantify the peroxide amount and texture profile data. A significance level of 5% was considered. The experimental bleaches CPa and CPc had the highest pH values when compared to the others in 6 months. Thickeners A and C did not change the pH, weight, and active content over the accelerated stability times (p > 0.05). Furthermore, there was weight loss after 3 months of storage for CPa and CPc (p < 0.05). In the quantification of hydrogen peroxide, the WP group showed the highest values over time (p < 0.0001), only showing a significant loss after the 3rd month. Meanwhile, CPa and CPc showed a reduction in quantification from the 1st month. Temperature and humidity directly influenced the active content and properties of bleaching gels. In addition, the presence of components regardless of thickeners, such as stabilizers, in the commercial gel allowed for greater stability over time. The development of experimental bleaching gels for clinical use requires careful testing. Therefore, accelerated stability testing represents a valuable tool in the development and evaluation of cosmetic formulations
Ver menos
COORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIOR - CAPES
001
Fechado
Effect of accelerated stability on the physical, chemical, and mechanical properties of experimental bleaching gels containing different bioadhesive polymers
Danielle Ferreira Sobral-Souza, Thayla Hellen Nunes Gouveia, André Luís Condeles, José Carlos Toledo Junior, Bruno Vilela Muniz, Michelle Franz-Montan, Maria Cibelle Pauli, Gislaine Ricci Leonardi, Débora Alves Nunes Leite Lima
Effect of accelerated stability on the physical, chemical, and mechanical properties of experimental bleaching gels containing different bioadhesive polymers
Danielle Ferreira Sobral-Souza, Thayla Hellen Nunes Gouveia, André Luís Condeles, José Carlos Toledo Junior, Bruno Vilela Muniz, Michelle Franz-Montan, Maria Cibelle Pauli, Gislaine Ricci Leonardi, Débora Alves Nunes Leite Lima
Fontes
|
Clinical oral investigations (Fonte avulsa) |