Using SPE-LC-ESI-MS/MS analysis to assess disperse dyes in environmental water samples
Guilherme Julião Zocolo, Glauco Pilon dos Santos, Josiane Vendemiatti, Francine Inforçato Vacchi, Gisela de Aragão Umbuzeiro, Maria Valnice Boldrin Zanoni
ARTIGO
Inglês
Agradecimentos: We acknowledge Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) for the post-doctoral fellowship given to G. J. Zocolo (Proc: 2011/00607-7) and financial support (Proc: 2008/10449-7). We extend our acknowledgments to Department of Water & Sewerage of City Americana-SP,...
Ver mais
Agradecimentos: We acknowledge Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) for the post-doctoral fellowship given to G. J. Zocolo (Proc: 2011/00607-7) and financial support (Proc: 2008/10449-7). We extend our acknowledgments to Department of Water & Sewerage of City Americana-SP, especially to its manager Guilherme Thiago Maziviero
Ver menos
Abstract: We have optimized an SPE-LC-ESI-MS/MS method and used it to monitor disperse azo dyes in environmental aquatic samples. Calibration curves constructed for nine disperse dyes - Red 1, Violet 93, Blue 373, Orange 1, Orange 3, Orange 25, Yellow 3, Yellow 7 and Red 13 - in aqueous solution...
Ver mais
Abstract: We have optimized an SPE-LC-ESI-MS/MS method and used it to monitor disperse azo dyes in environmental aquatic samples. Calibration curves constructed for nine disperse dyes - Red 1, Violet 93, Blue 373, Orange 1, Orange 3, Orange 25, Yellow 3, Yellow 7 and Red 13 - in aqueous solution presented good linearity between 2.0 and 100.0 ng mL-1. The method provided limits of detection and quantification around 2.0 and 8.0 ng L-1, respectively. For dyes at concentrations of 25.0 ng mL-1, the intra- and interday analyses afforded relative standard deviation lower than 6 and 13%, respectively. The recovery values obtained for each target analyte in Milli-Q water, receiving waters and treated water samples spiked with the nine studied dyes at concentrations of 8.0, 25.0 and 50.0 ng L-1 (n = 3) gave average recoveries greater than 70%, with RSD <20%. Statistical evaluation aided method validation. The validated method proved to be useful for analysis of organic extracts from effluents and receiving water samples after an SPE extraction step. More specifically, the method enabled detection of the dyes Disperse Red 1, Disperse Blue 373 and Disperse Violet 93 at concentrations ranging from 84 to 3452 ng L-1 in the treated effluent (TE), affluent and points collected upstream and downstream of the drinking water treatment plant of a textile dye industry in Brazil
Ver menos
FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESP
2008/10449-7; 2011/00607-7
Fechado
Using SPE-LC-ESI-MS/MS analysis to assess disperse dyes in environmental water samples
Guilherme Julião Zocolo, Glauco Pilon dos Santos, Josiane Vendemiatti, Francine Inforçato Vacchi, Gisela de Aragão Umbuzeiro, Maria Valnice Boldrin Zanoni
Using SPE-LC-ESI-MS/MS analysis to assess disperse dyes in environmental water samples
Guilherme Julião Zocolo, Glauco Pilon dos Santos, Josiane Vendemiatti, Francine Inforçato Vacchi, Gisela de Aragão Umbuzeiro, Maria Valnice Boldrin Zanoni
Fontes
|
Journal of chromatographic science (Fonte avulsa) |