Simulations of the electrostatic field, temperature, and tissue damage generated by multiple electrodes for electrochemical treatment
ARTIGO
Inglês
Agradecimentos: The authors appreciate the technical support provided by Mario Hechavarría Sánchez and Ana Elisa Bergues Pupo (Max Planck, Germany). We also thank Dr. Hugo Enrique Hernández Figueroa and Leonardo Lorenzo Bravo Roger for allowing the use of the Comsol Multiphysics® 4.4 software...
Agradecimentos: The authors appreciate the technical support provided by Mario Hechavarría Sánchez and Ana Elisa Bergues Pupo (Max Planck, Germany). We also thank Dr. Hugo Enrique Hernández Figueroa and Leonardo Lorenzo Bravo Roger for allowing the use of the Comsol Multiphysics® 4.4 software package. This study was supported by the Universidad de Oriente, Santiago de Cuba, Cuba [grant numbers 9811 and 9812]. Moreover, we give our special thanks to the Editor in Chief, Associate editor, and reviewers of this article for their expert help and invaluable feedback
Abstract: Integrated analysis of the spatial distributions of the electric potential, electric field, temperature, and tissue damage generated by multiple arrays of straight needle electrodes inserted into tumors is highly significant for improving the effectiveness of electrochemical treatment. In...
Abstract: Integrated analysis of the spatial distributions of the electric potential, electric field, temperature, and tissue damage generated by multiple arrays of straight needle electrodes inserted into tumors is highly significant for improving the effectiveness of electrochemical treatment. In this study, we simulated the spatial profiles generated by multiple electrodes inserted individually into a tumor and multiple pairs of straight needle electrodes inserted in a tumor surrounded by healthy tissue. Poisson nonlinear and Laplace equations were used to calculate the electric potential in the tumor and the surrounding healthy tissue, respectively. The stationary bioheat transfer equation of Pennes was used to calculate the temperature in both tissues. The percentage tissue damage was computed in each biological medium for each electrode array shape. Numerical simulations showed that the non-homogeneous spatial distributions of the temperature (above 40 degrees C) generated by different types of multiple pairs of straight needle electrodes covered the whole tumor volume. Spatial profiles of this physical magnitude were generated by multiple straight needle electrodes, which were individually inserted into the tumor and partially covered by its volume. In addition, the simulations showed that multiple pairs of electrodes led to tumor damage percentages above 80%. By contrast, multiple electrodes inserted individually in the tumor induced damage percentages below 25%. We conclude that multiple pairs of straight needle electrodes may be applied to deep-seated solid tumors in treatment with electrochemical therapy considering their theoretically calculated high tumor damage percentages
Fechado
Simulations of the electrostatic field, temperature, and tissue damage generated by multiple electrodes for electrochemical treatment
Simulations of the electrostatic field, temperature, and tissue damage generated by multiple electrodes for electrochemical treatment
Fontes
Applied mathematical modelling v. 76, p. 699-716, Dec. 2019 |