Can nonthermal plasma improve the adhesion between acrylic resin for ocular prostheses and silicone-based relining material?

Can nonthermal plasma improve the adhesion between acrylic resin for ocular prostheses and silicone-based relining material?

Bruna Egumi Nagay, Marcelo Coelho Goiato, Emily Vivianne Freitas da Silva, Rodrigo Antonio de Medeiros, Elidiane Cipriano Rangel, Nilson Cristino da Cruz, Fernanda Pereira de Caxias, Daniela Micheline dos Santos

ARTIGO

Inglês

Investigate the influence of nonthermal plasma (NTP) treatment on the tensile bond strength between heat-polymerized acrylic resin for ocular prostheses and silicone reliner, with and without the use of an adhesive primer. Materials and Methods One-hundred and sixty-four acrylic resin specimens were...

FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESP

2015/26169-7

Fechado

Can nonthermal plasma improve the adhesion between acrylic resin for ocular prostheses and silicone-based relining material?

Bruna Egumi Nagay, Marcelo Coelho Goiato, Emily Vivianne Freitas da Silva, Rodrigo Antonio de Medeiros, Elidiane Cipriano Rangel, Nilson Cristino da Cruz, Fernanda Pereira de Caxias, Daniela Micheline dos Santos

										

Can nonthermal plasma improve the adhesion between acrylic resin for ocular prostheses and silicone-based relining material?

Bruna Egumi Nagay, Marcelo Coelho Goiato, Emily Vivianne Freitas da Silva, Rodrigo Antonio de Medeiros, Elidiane Cipriano Rangel, Nilson Cristino da Cruz, Fernanda Pereira de Caxias, Daniela Micheline dos Santos

    Fontes

    Journal of prosthodontics

    Vol. 28, no. 6 (July, 2019), p. 692-700