Influence of using clinical microscope as auxiliary to perform mechanical cleaning of post space : a bond strength analysis
Ricardo Ferreira, Maíra Prado, Adrianade Jesus Soares, Alexandre Augusto Zaia, Francisco José de Souza-Filho
ARTIGO
Inglês
The aim of the present study was to evaluate the influence of using a clinical microscope while performing mechanical cleaning of post space walls on the bond strength of a fiberglass post to dentin. Forty-five bovine roots were used. After preparation, roots were filled using gutta-percha and Pulp...
Ver mais
The aim of the present study was to evaluate the influence of using a clinical microscope while performing mechanical cleaning of post space walls on the bond strength of a fiberglass post to dentin. Forty-five bovine roots were used. After preparation, roots were filled using gutta-percha and Pulp Canal Sealer (SybronEndo, Orange, CA). Subsequently, for post space preparation, the roots were divided into 3 groups: control (only heat condenser + specific bur of the post system); cleaning without a microscope, mechanical cleaning (after the procedure described in the control group, round burs were used to improve cleaning); and cleaning with a microscope, mechanical cleaning performed with round burs visualized under a clinical microscope. Then, fiberglass posts were cemented. The roots were prepared and evaluated by the push-out test. Data were analyzed using Kruskal-Wallis and Student-Newman-Keuls tests (P < .05). The failure pattern was classified as follows: adhesive between the cement and dentin, adhesive dentin/cement/post, mixed cohesive within dentin, mixed cohesive post, and mixed cohesive post/dentin. The bond strength values (mean ± standard deviation) were control (cervical 1.17 ± 1.1, middle 0.40 ± 0.3, apical 0.52 ± 0.3, and total 0.95 ± 1.9), cleaning without a microscope (cervical 1.66 ± 2.3, middle 0.65 ± 1.1, apical 0.79 ± 1.2, and total1.04 ± 1.7), and cleaning with a microscope (cervical 3.26 ± 2.8, middle 1.97 ± 3.5, apical 1.85 ± 4.1, and total 2.37 ± 3.5). In the cleaning with a microscope group, the bond strength values were significantly higher than those in the other groups. In all groups, the main failure pattern was adhesive between cement and dentin. The use of a clinical microscope while performing mechanical cleaning during post space preparation improved the bond strength of a fiberglass post to dentin.
Ver menos
Fechado
Influence of using clinical microscope as auxiliary to perform mechanical cleaning of post space : a bond strength analysis
Ricardo Ferreira, Maíra Prado, Adrianade Jesus Soares, Alexandre Augusto Zaia, Francisco José de Souza-Filho
Influence of using clinical microscope as auxiliary to perform mechanical cleaning of post space : a bond strength analysis
Ricardo Ferreira, Maíra Prado, Adrianade Jesus Soares, Alexandre Augusto Zaia, Francisco José de Souza-Filho
Fontes
Journal of endodontics (Fonte avulsa) |