Análise de fatores do instrumento de medida do impacto da doença no cotidiano
Rafaela Batista dos Santos Pedrosa, Roberta Cunha Matheus Rodrigues, Kátia Melissa Padilha, Maria Cecília Bueno Jayme Gallani, Neusa Maria Costa Alexandre
ARTIGO
Português
[Factor analysis of an instrument to measure the impact of disease on daily life]
Verificar a estrutura de fatores do Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata (IDCV) quando aplicado em coronariopatas. Método: fizeram parte deste estudo 153 coronariopatas em seguimento ambulatorial. A estrutura de fatores do IDCV foi inicialmente avaliada por meio...
Verificar a estrutura de fatores do Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata (IDCV) quando aplicado em coronariopatas. Método: fizeram parte deste estudo 153 coronariopatas em seguimento ambulatorial. A estrutura de fatores do IDCV foi inicialmente avaliada por meio da análise confirmatória de fatores e, subsequentemente, por meio da análise exploratória de fatores. Utilizou-se o método de estimação dos componentes principais de análise com rotação Varimax e eigenvalues acima de um para extração de fatores e carga fatorial superior a 0,40 para seleção dos itens. A consistência interna foi estimada por meio do coeficiente alfa de Cronbach. Resultados: a análise confirmatória não confirmou a estrutura original de fatores do IDCV. A análise exploratória de fatores evidenciou três dimensões que, em conjunto, explicaram 78% da variância da medida. Conclusão: estudos futuros com ampliação da casuística são necessários para confirmação da nova estrutura de fatores do IDCV
To verify the structure of factors of an instrument to measure the Heart Valve Disease Impact on Daily Life (IDCV) when applied to coronary artery disease patients. Method: the study included 153 coronary artery disease patients undergoing outpatient follow-up care. The IDCV structure of factors was...
To verify the structure of factors of an instrument to measure the Heart Valve Disease Impact on Daily Life (IDCV) when applied to coronary artery disease patients. Method: the study included 153 coronary artery disease patients undergoing outpatient follow-up care. The IDCV structure of factors was initially assessed by means of confirmatory factor analysis and, subsequently, by exploratory factor analysis. The Varimax rotation method was used to estimate the main components of analysis, eigenvalues greater than one for extraction of factors, and factor loading greater than 0.40 for selection of items. Internal consistency was estimated using Cronbach's alpha coefficient. Results: confirmatory factor analysis did not confirm the original structure of factors of the IDCV. Exploratory factor analysis showed three dimensions, which together explained 78% of the measurement variance. Conclusion: future studies with expansion of case selection are necessary to confirm the IDCV new structure of factors
Aberto
Análise de fatores do instrumento de medida do impacto da doença no cotidiano
Rafaela Batista dos Santos Pedrosa, Roberta Cunha Matheus Rodrigues, Kátia Melissa Padilha, Maria Cecília Bueno Jayme Gallani, Neusa Maria Costa Alexandre
Análise de fatores do instrumento de medida do impacto da doença no cotidiano
Rafaela Batista dos Santos Pedrosa, Roberta Cunha Matheus Rodrigues, Kátia Melissa Padilha, Maria Cecília Bueno Jayme Gallani, Neusa Maria Costa Alexandre
Fontes
Revista brasileira de enfermagem Vol. 69, no. 4 (jul./ago., 2016), p. 697-704 |