Cladding welding of CA6M with pulsed FCAW and results analysis through the L9 TAGUCHI and ANOVA

Cladding welding of CA6M with pulsed FCAW and results analysis through the L9 TAGUCHI and ANOVA

J. R. S. Moreno, H. C Pinto, C. A Correa, N. Mastelari, L. G. Marin, E. Silva, J.A. Ávila

ARTIGO

Inglês

The cladding welding analysis with pulsed flux cored arc welding (FCAW) process, were carried over a AISI 1020 base metal (thickness 12,7 mm, width 63,5 and length 185mm) with an CA6NM steel wire with diameter of 1.2mm. Was performed only one weld cord in the flat position. For experimental design...

Fechado

Cladding welding of CA6M with pulsed FCAW and results analysis through the L9 TAGUCHI and ANOVA

J. R. S. Moreno, H. C Pinto, C. A Correa, N. Mastelari, L. G. Marin, E. Silva, J.A. Ávila

										

Cladding welding of CA6M with pulsed FCAW and results analysis through the L9 TAGUCHI and ANOVA

J. R. S. Moreno, H. C Pinto, C. A Correa, N. Mastelari, L. G. Marin, E. Silva, J.A. Ávila

    Fontes

    International journal of advanced engineering research and science

    Vol. 5, no. 5 (May., 2018), p. 150-157