Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/332892
Type: TESE DIGITAL
Degree Level: Doutorado
Title: Efeito do comprimento e diâmetro do implante nas tensões induzidas por overdentures retidas por implante único : análise fotoelástica
Title Alternative: Effect of implant lenght and diameter on stress induced by single implant retained overdenture : photoelastic analysis
Author: Nogueira, Moises da Costa Ferraz, 1989-
Advisor: Consani, Rafael Leonardo Xediek, 1974-
Abstract: Resumo: O objetivo neste estudo foi verificar as tensões induzidas por overdentures suportadas por implante único com diferentes comprimentos e diâmetros em modelos fotoelásticos mandibulares, quando submetidas ao carregamento axial. Foram analisadas ovendentures mandibulares com sistema de retenção O¿ring tipo Equator e implantes cone Morse. Foi aplicado carregamento axial com intensidades de 10 e 30 kfg simulando a carga mastigatória entre as próteses maxilar e mandibular. Os modelos foram separados conforme as dimensões do implante cone Morse colocado na linha média da mandíbula: 1) Implantes com diâmetros de 3,5 mm e comprimentos de 7, 9 e 11 mm; 2) Implantes com diâmetros de 4,0 mm e comprimentos de 7, 9 e 11 mm; e 3) Implantes de com diâmetros de 5,0 mm de diâmetro e comprimentos de 7, 9 e 11 mm. Foram confeccionados 9 modelos mandibulares de resina fotoelástica formulada à base de bisfenol-A (Gy-279 BR) e endurecedor (HY 2964) em moldes de silicone. Uma prótese total convencional maxilar e três overdentures mandibulares foram confeccionadas nos modelos de gesso (uma para cada diâmetro de implante), feitas com resina acrílica. Para análise fotoelástica foi utilizada a técnica de transmissão plana, com polariscópio circular (PTH-A-01/LPM-UFU-MG) acoplado a uma câmera fotográfica digital, a qual gerou imagens para as análises qualitativas. Nos implantes com 3,5 mm de diâmetro os resultados foram: 7 mm de comprimento com tensão no ápice, redor do implante e área de rebordo alveolar; 9 mm de comprimento com tensão no terço médio para apical e lado esquerdo, aumentando a concentração com aumento da carga; e 11 mm de comprimento com tensão no corpo do implante, ápice e rebordo alveolar com o aumento da carga. Nos implantes com 4 mm de diâmetro os resultados foram: 7 mm de comprimento com concentração no ápice e rebordo alveolar com maior carga e menor tensão na área do rebordo alveolar; 9 mm de comprimento com tensão no corpo e ápice do implante, e rebordo alveolar com maior carga; 11 mm de comprimento com tensão no ápice, corpo e redor do implante com maior valor para a menor carga e distribuição homogênea com maior tensão. Nos implantes com 5 mm de diâmetro os resultados foram: 7 mm de comprimento com concentração similar da tensão no ápice com ambas as cargas e maior valor para a maior carga; 9 mm de comprimento com tensão no ápice e redor do implante com aumento da carga; 11 mm de comprimento com tensão ao longo e ápice do implante em ambas as cargas. Em conclusão, maior comprimento dos implantes proporcionou melhor distribuição de tensões no ápice, corpo do implante e rebordo alveolar. Maior diâmetro (5,0mm) concentrou tensões ao redor do implante. O aumento da carga aplicada proporcionou maior quantidade de tensão induzida no implante e mais homogênea distribuição de tensão ao rebordo alveolar

Abstract: The purpose of this study was to verify the stress induced by single implant retained overdentures with different diameter (3.5, 4.0 and 5.0 mm) and lengths (7, 9 and 11 mm) in mandibular photoelastic models submitted to loadings (10 and 30 kgf). Mandibular overdentures were made by using traditional method with O¿ring retention supported by morse connection implant. Axial loads were applied with intensities of 10 and 30 kgf simulating the masticatory load between maxillary and mandibular dentures. The models were divided according to implant dimensions into the following groups: 1) Implants with 3.5 mm-diameter and 7, 9 and 11 mm-lenght, placed in the median line of the mandible; 2) Implants with 4 mm-diameter and 7, 9 and 11 mm-lenght, placed in the median line of the mandible; and 3) Implants with 5 mm-diameter and 7, 9 and 11 mm- length, placed in the median line of the mandible. In silicone mold were made 9 photoelastic resin mandibular models formulated with bisphenol A (Gy-279 BR) and hardener (HY 2964). One conventional maxillar denture and three mandibular overdentures were made. The denture bases were made with acrylic resin. In the photoelastic analysis were utilized the plan transmission technique, with circular polariscope attached with digital camera, which produced the images for qualitative analyses. In the implants with 3.5 mm-diameter the results were: 7 mm-length with stress at apex, around the implant and alveolar ridge; 9 mm-length with stress at middle third to apical, and left side, increasing the concentration with the load increase; and 11 mm-length with stress at along the implant apex, and alveolar ridge with the load increase. In the implants with 4 mm-diameter the results were: 7 mm-length with stress at apex concentration with greater load and lesser stress in the alveolar ridge; 9 mm-length with stress along the implant and apex with greater load; 11 mm-length with stress at apex, along and around the implant with greater value for smaller load, and homogeneous distribution with greater stress. In the implants with 5 mm-diameter the results were: 7 mm-length with similar concentration at apex for both loads and greater value for greater load; 9 mm-length with stress at apex and around the implant with load increase; 11 mm-length with stress along and apex of the implant for both loads. In conclusion, greater length of the implants promoted better stress distribution at apex, along the implant, and alveolar ridge. Greater diameter (5.0 mm) concentrates more stress around the implants. Increase of load applied promoted greater amount of induced stress in the implant, and homogeneous distribution of stress to alveolar ridge
Subject: Implantes dentários
Fotoelasticidade
Revestimento de dentadura
Language: Português
Editor: [s.n.]
Citation: NOGUEIRA, Moises da Costa Ferraz. Efeito do comprimento e diâmetro do implante nas tensões induzidas por overdentures retidas por implante único: análise fotoelástica. 2018. 1 recurso online (70 p.). Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP.
Date Issue: 2018
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Nogueira_MoisesDaCostaFerraz_D.pdf1.67 MBAdobe PDFView/Open