Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/304944
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.descriptionOrientador: Mauro Antonio de Arruda Nóbilopt_BR
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicabapt_BR
dc.descriptionAgência de fomento:pt_BR
dc.descriptionAgência de fomento:pt_BR
dc.format.extent1 recurso online ( 70 p.) : il., digital, arquivo PDF.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.relation.requiresRequisitos do sistema: Software para leitura de arquivo em PDFpt_BR
dc.typeDISSERTAÇÃO DIGITALpt_BR
dc.titleAnálise da exatidão em modelos de gesso após diferentes técnicas de captura em implantodontiapt_BR
dc.title.alternativeAnalysis of accuracy in casts after different techniques of capture in implantologypt_BR
dc.contributor.authorAzevedo, Veber Luiz Bomfim, 1988-pt_BR
dc.contributor.advisorNóbilo, Mauro Antonio de Arruda, 1965-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Odontologia de Piracicabapt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Clínica Odontológicapt_BR
dc.subjectTécnica de moldagem odontológicapt_BR
dc.subjectTensão superficialpt_BR
dc.subjectImplantes dentáriospt_BR
dc.subject.otherlanguageDental impression techniqueen
dc.subject.otherlanguageSurface tensionen
dc.subject.otherlanguageDental implantsen
dc.description.abstractResumo: Este estudo avaliou quatro diferentes técnicas de moldagem de captura em implantodontia quanto a exatidão dimensional dos modelos de gessos. Foram obtidos quatro grupos (n=10): PF- transferentes unidos com resina Pattern e fio dental; PP- transferentes unidos com barras de resina acrílica pré-fabricada e resina Pattern; OC- transferentes unidos com elastômero para registro de mordida de polivinilsiloxano; MP- transferentes unidos com haste metálica e resina Pattern. Os dados de tensões induzidas aos implantes e desadaptação marginal foram analisados individualmente para verificar a normalidade dos dados, utilizando o teste Kolmogorov-Smirnov, a qual não foi confirmada, optando-se, por testes não paramétricos. Os dados de deformação foram tabulados e submetidos ao teste de Kruskal-Wallis (p = 0,05) para comparação das variáveis desadaptação total, tensão total, cervical e apical entre os implantes (1, 2, 3 e 4) e, quando constatou-se diferença significativa, utilizou-se o teste de Dunn para realização da comparação múltipla. A correlação de Spearman foi utilizada para verificação da relação entre tensão total e desadaptação. Para desadaptação, houve diferenças significativas entre os grupos nos implantes 2, 3 e 4 (p=0,0018; <0,0001 e 0,0005 respectivamente). Diferenças ocorreram no implante 2 entre Grupo PF/PP (17,3 µm) e Grupo PF/OC (17,65 µm); implante 3, entre o Grupo PF/MP (19,65 µm) e Grupo PF/OC (24,8 µm); implante 4 entre o Grupo PF/MP (15,5 µm) e Grupo PF/OC (14 µm). Com relação a tensão cisalhante total, houve diferença significativa entre os grupos no implante 2 (p=0,002). As diferenças ocorreram entre o Grupo MP/PP (40.0 kgf) e Grupo MP/OC (46.4 kgf). Não foram observadas diferenças estatísticas entre os grupos para os implantes 1, 3 e 4 (p= 0,141; 0,264; 0,058 respectivamente). O Grupo MP apresentou os menores valores de tensão cisalhante e ordem de franja e o Grupo OC os maiores. Houve correlação positiva, porém fraca (0,4) entre desadaptação e tensão. Todos os métodos de esplitangem produziram alterações no modelo de trabalho para prótese total sobre 4 implantespt
dc.description.abstractAbstract: This study compared four different capture molding techniques in implant dentistry on the dimensional accuracy of plaster models. Four groups were obtained (n = 10): PF - transfer copings together with floss and Pattern resin; PP - transfer united with prefabricated acrylic resin bars and Pattern resin; OF - transfer united with polyvinylsiloxane bite registration; MP -transfer united with metal rod and Pattern resin. The data of tension induced to implants and marginal misfit was analyzed in order to verify data normality using the Kolmogorov-Smirnov test, which was not confirmed, opting, for non-parametric tests. The strain data were compiled and submitted to the Kruskal-Wallis test (p = 0,05) for comparison of the variables overall misfit, total, cervical and apical tension between the implants (1, 2, 3 and 4) and, when it was found significant difference the Dunn's test was used for multiple comparison. The Spearman correlation was used to verify the relationship between total stress and misfit. To misfit, there were significant differences between the groups in the implants 2, 3 and 4 (p = 0.0018, < 0,0001 and 0,0005 respectively). Differences happen in the implant 2 between PF/PP group (17,3 µm) and PF/OC group (17,65 µm); implant 3, between the PF/MP group (19,65 µm) and PF/OC group (24,8 µm); 4 implant between the PF/MP group (15,5 µm) and PF/OC group (14 µm) With respect to the total shear tension, there was a significant difference between the groups in the implant 2 (p = 0,002). The differences occurred between the MP/PP group (40,0 kgf) and MP/OC group (46,4 kgf). There were no statistical differences between the groups for the implants 1, 3 and 4 (p = 0,141; 0,264; 0,058 respectively). The MP group showed the lowest shear tension values and order fringe and the OC group the biggest. There was a positive but weak correlation (0,4) between misfit and tension. All splinting methods produced changes in the working model for denture on 4 implantsen
dc.publisher[s.n.]pt_BR
dc.date.issued2016pt_BR
dc.identifier.citationAZEVEDO, Veber Luiz Bomfim. Análise da exatidão em modelos de gesso após diferentes técnicas de captura em implantodontia. 2016. 1 recurso online ( 70 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/304944>. Acesso em: 30 ago. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplineProtese Dentalpt_BR
dc.description.degreenameMestre em Clínica Odontológicapt_BR
dc.contributor.committeepersonalnameReis, José Maurício dos Santos Nunespt_BR
dc.contributor.committeepersonalnameConsani, Rafael Leonardo Xediekpt_BR
dc.date.available2018-08-30T10:28:54Z-
dc.date.accessioned2018-08-30T10:28:54Z-
dc.description.provenanceMade available in DSpace on 2018-08-30T10:28:54Z (GMT). No. of bitstreams: 1 Azevedo_VeberLuizBomfim_M.pdf: 2311964 bytes, checksum: a320098d613b9b08751af2d781b9f423 (MD5) Previous issue date: 2016en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/304944-
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Azevedo_VeberLuizBomfim_M.pdf2.26 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.