Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/287909
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.descriptionOrientadores: Marcio Zaffalon Casati, Francisco Humberto Nociti Juniorpt_BR
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicabapt_BR
dc.format.extent67 f. : il.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.typeDISSERTAÇÃOpt_BR
dc.titleEfeito do meloxicam sobre o reparo osseo ao redor de implantes de titaniopt_BR
dc.title.alternativeEffect of meloxicam on bone healing around titanium implantspt_BR
dc.contributor.authorRibeiro, Fernanda Vieirapt_BR
dc.contributor.advisorCasati, Márcio Zaffalon, 1973-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Odontologia de Piracicabapt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Clínica Odontológicapt_BR
dc.subjectAnti-inflamatóriospt_BR
dc.subjectCicloxigenasespt_BR
dc.subjectImplantes dentáriospt_BR
dc.subject.otherlanguageAnti-inflammatory agentsen
dc.subject.otherlanguageCyclooxygenasesen
dc.subject.otherlanguageDental implantsen
dc.subject.otherlanguageBone regenerationen
dc.description.abstractResumo: O objetivo deste estudo foi avaliar a influência de um antiinflamatório não esteroidal inibidor seletivo de COX-2, meloxicam, sobre o reparo ósseo ao redor de implantes de titânio colocados em tíbias de ratos. Foram utilizados 31 ratos Wistar, machos, adultos, os quais receberam um implante dental de titânio em uma das tíbias. Após a colocação dos implantes, os animais foram aleatoriamente incluídos nos seguintes grupos: Controle (n=14): 1 ml/kg de solução fisiológica de cloreto de sódio a 0,9% esterilizada e Teste (n=17): 3 mg/kg de meloxicam, ambos administrados via subcutânea, diariamente, durante 60 dias. Os animais foram mortos após 60 dias da cirurgia de colocação dos implantes. Secções não descalcificadas foram obtidas e avaliadas histometricamente. Foram avaliados os seguintes parâmetros: porcentagem de tecido ósseo em contato direto com a superfície do implante (CD), porcentagem de preenchimento ósseo dentro das roscas do implante (PR) e porcentagem de osso numa região 500 µm adjacente à superfície do implante (OA). Os dados foram obtidos separadamente para região cortical (A) e região medular (B). O teste não paramétrico de Mann-Whitney (a= 5%) foi utilizado para a análise estatística. Os resultados demonstraram que o meloxicam reduziu significativamente o reparo ósseo ao redor dos implantes. Para a região A, diferenças significantes foram observadas com relação ao CD (47,01 ± 10,48 A; 35,93 ± 12,25 B), PR (86,42 ± 3,66 A; 61,58 ± 12,09 B) e OA (96,86 ± 0,96 A; 91,06 ± 3,05 B), entre os grupos controle e teste, respectivamente (p<0,05). Para a região B, a análise dos dados também mostrou diferenças significantes entre os grupos controle e teste, respectivamente (p<0,05), para CD (30,76 ± 13,80 A; 16,86 ± 11,48 B), PR (34,83 ± 8,18 A; 25,66 ± 9,16 B) e AO (15,76 ± 7,05 A; 7,73 ± 4,61 B). Dentro dos limites do presente estudo, concluiu-se que a administração de 3 mg/kg/dia de meloxicam influenciou negativamente o reparo ósseo, tanto no osso cortical quanto medular, ao redor de implantes de titânio inseridos em tíbias de ratospt
dc.description.abstractAbstract: The aim of this study was to investigate the effect of a selective cyclooxygenase-2 inhibitor, meloxicam, on bone healing around titanium implants in rats. Thirty-one adult male Wistar rats were included in this study and one screw-shaped titanium implant was inserted in the tibiae. The animals were randomly assigned to one of the following groups, for daily subcutaneous injections: Control (n=14): 1 ml/kg of saline solution and Test (n=17): 3 mg/kg of meloxicam, each administered daily for 60 days. After the treatment, the animals were sacrificed and undecalcified sections obtained. Bone-to-implant contact (BIC) and bone filling within the limits of of implant threads (BF) and percentage of bone in a 500µm-wide zone lateral to the implant (BL) were obtained and arranged for cortical (zone A) and cancellous (zone B) bone regions. The data were tested by the Mann-Whitney test (a= 5%). Intergroup comparisons demonstrated that meloxicam significantly reduced bone healing around implants. For zone A, significant differences were observed regarding BIC (47.01 ± 10.48 A; 35.93 ± 12.25 B), BF (86.42 ± 3.66 A; 61.58 ± 12.09 B) and BL (96.86 ± 0.96 A; 91.06 ± 3.05 B) for control and test groups, respectively (p<0.05). For zone B, data analysis also showed significant differences among the groups for BIC (30.76 ± 13.80 A; 16.86 ± 11.48 B), BF (34.83 ± 8.18 A; 25.66 ± 9.16 B) and BL (15.76 ± 7.05 A; 7.73 ± 4.61 B) for control and test groups, respectively (p<0.05). In conclusion, within the limits of the present study, 3 mg/kg/day of meloxicam may negatively influence bone healing in the cortical and cancellous bone around titanium implants inserted in rats after continuous administrationen
dc.publisher[s.n.]pt_BR
dc.date.issued2007pt_BR
dc.identifier.citationRIBEIRO, Fernanda Vieira. Efeito do meloxicam sobre o reparo osseo ao redor de implantes de titanio. 2007. 67 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/287909>. Acesso em: 8 ago. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplinePeriodontiapt_BR
dc.description.degreenameMestre em Clínica Odontológicapt_BR
dc.contributor.committeepersonalnameRomito, Giuseppe Alexandrept_BR
dc.contributor.committeepersonalnameSallum, Enilson Antoniopt_BR
dc.date.defense2007-02-28T00:00:00Zpt_BR
dc.date.available2018-08-08T10:03:39Z-
dc.date.accessioned2018-08-08T10:03:39Z-
dc.description.provenanceMade available in DSpace on 2018-08-08T10:03:39Z (GMT). No. of bitstreams: 1 Ribeiro_FernandaVieira_M.pdf: 6226415 bytes, checksum: b38d7ee0ba1cf539da8c71788c69fbad (MD5) Previous issue date: 2007en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/287909-
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Ribeiro_FernandaVieira_M.pdf6.08 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.