Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/27356
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.contributor.authorunicampGirotto, Marcos Antoniopt_BR
dc.contributor.authorunicampRanali, Josépt_BR
dc.contributor.authorunicampVolpato, Maria Cristinapt_BR
dc.typeArtigopt_BR
dc.titleAvaliação da padronização de agulhas anestésicas odontológicas comercializadas no Brasilpt_BR
dc.title.alternativeEvaluation of the standardization of injection dental needles marketed in Brazilen
dc.contributor.authorGirotto, Marcos Antoniopt_BR
dc.contributor.authorRanali, Josépt_BR
dc.contributor.authorVolpato, Maria Cristinapt_BR
dc.subjectControle de qualidadept_BR
dc.subjectOdontologiapt_BR
dc.subject.otherlanguageQuality controlpt_BR
dc.subject.otherlanguageDentistrypt_BR
dc.description.abstractThe standardization of sterile, single-use dental injection needles marketed in Brazil in 1997 was evaluated. The effective needle length (L1), butt end length (L2), socket depth (L3), external (ED) and internal (ID) diameters, corrosion resistance of the cannula, and the information printed on the package (unitary protector and box) were evaluated. The data were compared with the International Standard (ISO), American specification no. 54 (ANSI/ADA) and French Standard (FS). There were great variations for L1, L2, L3 and ID, and no trade mark fitted in any of the standards for all the dimensions. The external diameter showed very little variation in all the trade marks according to the ANSI/ADA and FS. All of the needles withstood the corrosion test. Some trade marks had incomplete information in their package and one of them had no expiration date. Some of the unitary protectors, once opened, did not show clear evidence of having been violated. These results show the need for a Brazilian specification to regulate the manufacturing of single-use dental injection needles.en
dc.description.abstractForam avaliadas neste trabalho agulhas anestésicas odontológicas descartáveis, comercializadas no Brasil no segundo semestre de 1997, quanto às medidas: comprimento da cânula, da porção que perfura o tubete e da porção que permanece no interior do adaptador plástico e diâmetros externo e interno. A resistência à corrosão da cânula e as informações da embalagem (caixa e protetor) também foram avaliadas. Os resultados foram comparados com as normas Internacional (ISO)8, Americana (ANSI/ADA)¹ e Francesa (NF). Foram observadas variações, não havendo uma só marca que estivesse de acordo com qualquer das normas, para todas as medidas. Todas as agulhas atingiram as especificações do teste de corrosão. Algumas embalagens mostraram conteúdo de informação incompleto e uma marca estava sendo vendida sem prazo de validade. Alguns protetores não permitiam identificar a violação do lacre, quando isto ocorria. Estes resultados demonstram a necessidade de se estabelecerem normas brasileiras, para regulamentar a produção e venda de agulhas odontológicas no paíspt
dc.relation.ispartofPesquisa odontológica brasileirapt_BR
dc.relation.ispartofabbreviationPesqui. odontol. bras.pt_BR
dc.publisher.citySão Paulo, SPpt_BR
dc.publisher.countryBrasilpt_BR
dc.publisherSociedade Brasileira de Pesquisa Odontologicapt_BR
dc.date.issued2000pt_BR
dc.date.monthofcirculationjul./set.pt_BR
dc.identifier.citationPesquisa Odontológica Brasileira. Sociedade Brasileira de Pesquisa Odontológica e Faculdade de Odontologia da Universidade de São Paulo, v. 14, n. 3, p. 294-299, 2000.pt_BR
dc.language.isoporpt_BR
dc.description.volume14pt_BR
dc.description.issuenumber3pt_BR
dc.description.firstpage294pt_BR
dc.description.lastpage299pt_BR
dc.rightsabertopt_BR
dc.sourceSciELOpt_BR
dc.identifier.issn1517-7491pt_BR
dc.identifier.eissn1678-8079pt_BR
dc.identifier.doi10.1590/S1517-74912000000300019 pt_BR
dc.identifier.urlhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1517-74912000000300019pt_BR
dc.description.sponsorshipCNPQ - CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICOpt_BR
dc.description.sponsorship1CNPQ - CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICOpt_BR
dc.description.sponsordocumentnumber136992/96-0pt_BR
dc.date.available2014-07-17T17:55:57Z-
dc.date.available2015-11-26T13:01:38Z-
dc.date.accessioned2014-07-17T17:55:57Z-
dc.date.accessioned2015-11-26T13:01:38Z-
dc.description.provenanceMade available in DSpace on 2014-07-17T17:55:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-09-01 Bitstreams deleted on 2020-05-14T20:38:00Z: S1517-74912000000300019.pdf,en
dc.description.provenanceMade available in DSpace on 2015-11-26T13:01:38Z (GMT). No. of bitstreams: 2 S1517-74912000000300019.pdf: 77962 bytes, checksum: f73659c620f4ce46d0377ee9da16f606 (MD5) S1517-74912000000300019.pdf.txt: 22698 bytes, checksum: 9fcca159d643f9c724a0f6ffcc2f6409 (MD5) Previous issue date: 2000-09-01en
dc.identifier.urihttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/27356-
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/27356-
dc.contributor.departmentSem informaçãopt_BR
dc.contributor.departmentDepartamento de Ciências Fisiológicaspt_BR
dc.contributor.departmentDepartamento de Ciências Fisiológicaspt_BR
dc.contributor.unidadeFaculdade de Odontologia de Piracicabapt_BR
dc.contributor.unidadeFaculdade de Odontologia de Piracicabapt_BR
dc.contributor.unidadeFaculdade de Odontologia de Piracicabapt_BR
dc.description.abstractalternativeThe standardization of sterile, single-use dental injection needles marketed in Brazil in 1997 was evaluated. The effective needle length (L1), butt end length (L2), socket depth (L3), external (ED) and internal (ID) diameters, corrosion resistance of the cannula, and the information printed on the package (unitary protector and box) were evaluated. The data were compared with the International Standard (ISO), American specification no. 54 (ANSI/ADA) and French Standard (FS). There were great variations for L1, L2, L3 and ID, and no trade mark fitted in any of the standards for all the dimensions. The external diameter showed very little variation in all the trade marks according to the ANSI/ADA and FS. All of the needles withstood the corrosion test. Some trade marks had incomplete information in their package and one of them had no expiration date. Some of the unitary protectors, once opened, did not show clear evidence of having been violated. These results show the need for a Brazilian specification to regulate the manufacturing of single-use dental injection needles-
dc.subject.keywordAgulhaspt_BR
dc.identifier.sourceS1517-74912000000300019 -
dc.creator.orcidSem informaçãopt_BR
dc.creator.orcid0000-0002-4623-000Xpt_BR
dc.creator.orcid0000-0002-1459-7050pt_BR
dc.type.formArtigopt_BR
Appears in Collections:FOP - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
S1517-74912000000300019.pdf532.73 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.