Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/261433
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.identifier(Broch.)pt_BR
dc.descriptionOrientador : Ioshiaki Doipt_BR
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletricapt_BR
dc.format.extent111f.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.typeDISSERTAÇÃOpt_BR
dc.titleSobretensões em cadeia de isoladores frente a descargas atmosfericas : um estudo comparativo dos metodos de calculo e do parametro Ztpt_BR
dc.contributor.authorGodoy, Antonio Varejao dept_BR
dc.contributor.advisorDoi, Ioshiaki, 1944-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Engenharia Elétricapt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Ciênciaspt_BR
dc.subjectEnergia elétricapt_BR
dc.subjectTestes elétricospt_BR
dc.subjectEngenharia elétricapt_BR
dc.description.abstractResumo: Este t.rabalho estuda de uma forma determinística as sobretensões em cadeias de isoladores, que surgem quando uma descarga atmosférica atinge o topo de uma torre de transmissão . São analisados e comparados os métodos de cálculo deste tipo de sobretensões : o método das relações sucessivas, elaborado por Jordan e o método de campo proposto inicialmente por Wagner. Para atingir este objetivo, desenvolve-se um programa computacional que calcula a sobretensão quando a descarga atinge o topo da torre de um sistema de transmissão pelas duas abordagens. Fundamentado nesta análise, escolhe-se o método mais simples e eficiente. Posteriormente, utilizando-se este método .ê feita uma análise de sensibilidade simplificada para quatro parêmetros: impedância do canal da descarga, impedância de pé-de-torre, tempo de subida da forma de onda da descarga e impedância de surto de torre. Esta análise é feita com a finalidade de verificar a variação da magnitude da tensão na cadeia de isoladores. Finalmente destaca-se a impedância de surto de torre comparando modelos convencionais (Jordan , Wagner, Wagner modificado, Daverniza e Método Simplificado ) com os valores medidos em ensaios com torres em escala reduzida. escala reduzidapt
dc.description.abstractAbstract : This work studies in à deterministic point of view a lightning discharges that strikes directly the transmission line tower top. The calculation methods of this kind of surges : the method of successive reflections, introduced by Jordan and the method of field conceptions, firstly developed by Wagner, are reviewed , analysed as well as compared with these purpose. Based on this two approaches a computacional program is developed to calculate the overvoltage on the insulator string and the required parameters. Based on the results of this analysis, the simplest and most efficient method is chosen and where a simple sensitivity anal ysis is made for the following the tower parameters: the i mpedance of lightning stroke channel , the tower food impedance, time to crest of stroke shape function and tower surge impedance. This analysis is performed in order to verify the voltage variation on the i nsulators string. Finally. the last parameter, the tower surge impedance is enphasized comparing its calculated values with the measured values by geometrical model techniqueen
dc.publisher[s.n.]pt_BR
dc.date.issued1989pt_BR
dc.identifier.citationGODOY, Antonio Varejao de. Sobretensões em cadeia de isoladores frente a descargas atmosfericas: um estudo comparativo dos metodos de calculo e do parametro Zt. 1989. 111f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica, Campinas, [SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/261433>. Acesso em: 16 jul. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreenameMestre em Ciênciaspt_BR
dc.date.defense1989-07-21T00:00:00Zpt_BR
dc.date.available2018-07-16T04:06:30Z-
dc.date.accessioned2018-07-16T04:06:30Z-
dc.description.provenanceMade available in DSpace on 2018-07-16T04:06:30Z (GMT). No. of bitstreams: 1 Godoy_AntonioVarejaode_M.pdf: 7751664 bytes, checksum: 770c1be6d4d3861c9ad734b8c7c470f1 (MD5) Previous issue date: 1989en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/261433-
Appears in Collections:FEEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Godoy_AntonioVarejaode_M.pdf7.57 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.