dc.titleMedição minimamente invasiva da pressão vesical no homem : instrumentação e aplicação clínicapt_BR
dc.title.alternativeMinimally invasive measurement of vesical pressure in men : instrumentation and clinical applicationpt_BR
dc.contributor.authorAlmeida, João Carlos Martins de, 1987-pt_BR
dc.contributor.advisorBassani, José Wilson Magalhães, 1953-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Engenharia Elétricapt_BR
dc.subjectInstrumentaçãopt_BR
dc.subjectSintomas do trato urinário inferiorpt_BR
dc.subjectUrodinâmicapt_BR
dc.subjectProstatapt_BR
dc.subjectMétodos - Validaçãopt_BR
dc.subject.otherlanguageInstrumentationen
dc.subject.otherlanguageSymptoms of lower urinary tracten
dc.subject.otherlanguageUrodynamicsen
dc.subject.otherlanguageProstateen
dc.subject.otherlanguageMethods - Validationen
dc.description.abstractResumo: O estudo urodinâmico tem importante papel na determinação da necessidade de pacientes portadores de sintomas do trato urinário inferior (STUI) se submeterem à cirurgia da próstata. O estudo pressão-fluxo pode contribuir muito para a quantificação dos STUI, porém é invasivo, demorado e de custo elevado. Métodos alternativos têm sido desenvolvidos procurando minimizar o procedimento invasivo necessário para medição da pressão vesical. Um método alternativo foi desenvolvido no Centro de Engenharia Biomédica da UNICAMP e consiste num dispositivo denominado conector uretral (Pat. N. PI 0502171-5). Trata-se de um dispositivo cilíndrico e vazado, que permite o escoamento de urina por seu interior. O paciente é orientado a introduzir o conector na uretra antes de iniciar a micção e, ao urinar, solicitado a ocluir a saída do dispositivo, interrompendo o fluxo urinário por um curto intervalo e permitindo o registro da pressão dentro da bexiga urinária. Neste trabalho, uma instrumentação e uma nova versão do conector uretral foram desenvolvidas para medir a pressão vesical em homens. Aplicado em testes clínicos em indivíduos com sintomas de obstrução infravesical decorrente de hiperplasia benigna da próstata, o conjunto demonstrou capacidade de diferenciar indivíduos com obstrução de indivíduos não obstruídos sem diferença significativa do que se obtém no estudo pressão-fluxo (p > 0,05). O conector apresentou sensibilidade e especificidade de 66,7%, valores similares aos dos métodos alternativos descritos na literatura. Além disso, 88,5% dos indivíduos relataram preferir o conector uretral ao estudo pressão-fluxo, indicando a importância do conector como método alternativo minimamente invasivo ao estudo urodinâmico convencionalpt
dc.description.abstractAbstract: Urodynamic assessment has an important role in the decision of patients complaining of lower urinary tract symptoms (LUTS) to undergo prostate surgery. Pressure-flow study may contribute to the evaluation of LUTS, but its procedure is invasive, time-consuming and expensive. Alternative methods have been developed aiming at measuring vesical pressure in a less invasive manner. An alternative method was developed in the Center for Biomedical Engineering at UNICAMP and consists of a device named urethral connector (Pat. N. PI 0502171-5). The device has a cylindrical shape and an internal longitudinal hole that permits urine to pass through it. The patient is instructed to insert the urethral connector into his urethra before starting to urinate. During micturition, he is instructed to occlude the urine outlet of the device for a short period of time so that vesical pressure may be measured. In this work, an instrumentation and a new version of the urethral connector were developed to measure vesical pressure in men. The device and instrumentation were applied in clinical tests in individuals reporting LUTS secondary to infravesical obstruction due to benign prostatic hyperplasia. It was shown that this new method is capable of differentiating obstructed individuals from nonobstructed ones. Results were not significantly different from those obtained when conventional pressure-flow study was applied (p > 0.05). The urethral connector had a sensibility and specificity of 66.7%, values similar to those found by the alternative methods described in the literature. About 88.5% of the individuals evaluated reported to prefer the new method instead of the conventional assessment which reinforces the importance of the urethral connector as a less invasive and alternative method to the conventional urodynamic studyen
dc.publisher[s.n.]pt_BR
dc.date.issued2014pt_BR
dc.identifier.citationALMEIDA, João Carlos Martins de. Medição minimamente invasiva da pressão vesical no homem: instrumentação e aplicação clínica. 2014. 50 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/259390>. Acesso em: 26 ago. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplineEngenharia Biomedicapt_BR
dc.description.degreenameMestre em Engenharia Elétricapt_BR
dc.contributor.committeepersonalnameButton, Sergio Toninipt_BR
dc.contributor.committeepersonalnameMuhlen, Sérgio Santospt_BR
dc.date.available2018-08-26T12:41:31Z-
dc.date.accessioned2018-08-26T12:41:31Z-
dc.description.provenanceMade available in DSpace on 2018-08-26T12:41:31Z (GMT). No. of bitstreams: 1 Almeida_JoaoCarlosMartinsde_M.pdf: 13918269 bytes, checksum: 78378428b79af0919ecab395a454bf98 (MD5) Previous issue date: 2014en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/259390-
Appears in Collections:FEEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Almeida_JoaoCarlosMartinsde_M.pdf13.59 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.