Eletrodeposição pulsada para a remoção e reúso do cobre de efluentes industriais e a formação de revestimentos de NiCu resistentes à corrosão [recurso eletrônico] = Pulsed electrodeposition for the removal and reuse of copper from industrial wastewater with produciton of NiCu corrosion resistant coating
Thayane Carpanedo de Morais Nepel
TESE
Português
T/UNICAMP N351e
[Pulsed electrodeposition for the removal and reuse of copper from industrial wastewater with produciton of NiCu corrosion resistant coating]
Campinas, SP : [s.n.], 2019.
1 recurso online (132 p.) : il., digital, arquivo PDF.
Orientadores: Ambrósio Florêncio de Almeida Neto, Melissa Gurgel Adeodato Vieira
Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química
Resumo: A recuperação de metais advindos de efluentes é uma problemática recorrente devido às inúmeras atividades produtivas que geram resíduos aquosos com elevadas concentrações de metais tóxicos. Nesse âmbito, este trabalho tem por objetivo a otimização da recuperação de cobre e a formação de...
Ver mais
Resumo: A recuperação de metais advindos de efluentes é uma problemática recorrente devido às inúmeras atividades produtivas que geram resíduos aquosos com elevadas concentrações de metais tóxicos. Nesse âmbito, este trabalho tem por objetivo a otimização da recuperação de cobre e a formação de compostos NiCu, a partir de efluente industrial, utilizando eletrodeposição pulsada. Assim, foi utilizada a cronoamperometria pulsada, como método de deposição, avaliando a corrente elétrica aplicada, a temperatura do banho e a rotação do cátodo. O processo otimizado para obtenção de cobre metálico apresentou uma remoção de 33,59 % de cobre, com uma eficiência de deposição de 84,36 % em 30 minutos, utilizando cronoamperometria pulsada rápida, ton= 1ms, 190 mA, 70 rpm e 37 °C. O estudo da cinética desse processo possibilitou ainda, a remoção de 82,49% a 37 °C com 115 min de duração. Os resultados mostraram que na faixa de temperatura entre 20 °C e 40 °C o processo pode ser descrito pelo modelo de pseudo primeira ordem, considerando a reação irreversível. Com a variação dos parâmetros avaliados, foi possível a remoção do cobre com formação de óxidos cristalinos até cobre cristalino na sua forma metálica. Os experimentos conduzidos nas temperaturas de 10 °C e 50 °C indicaram que a reação paralela de formação do óxido de cobre I é favorecida nessas temperaturas. O estudo para obtenção dos revestimentos NiCu possibilitou a determinação dos parâmetros ótimos para produção de um material homogêneo, nanocristalino, com composição semelhante ao da liga Monel comercial e apresentando elevada resistência à corrosão em NaCl 3,5 %. Os parâmetros ótimos foram pH 9, 0,200 mol/L de Ni+2, 600 mA, ton= 1ms, 20 rpm, 40 °C em substrato de cobre. Essa pesquisa apontou a influência significativa da concentração de níquel, corrente elétrica de deposição e rotação do substrato sobre a eficiência de deposição e composição da liga metálica, ressaltando a importância da baixa rotação para obter revestimentos com maior concentração de níquel e homogêneos, implicando no aumento da resistência à corrosão. Por meio dos mecanismos de avaliação utilizados, concluiu-se que a técnica de eletrodeposição pulsada rápida, para a redução dos íons metálicos em solução é viável e apresentou grande potencial de remoção e reuso de metais advindos de efluentes
Ver menos
Abstract: The recovery of metals from wastewater is a recurrent a problem due to large number of manufacturing process that generate wastewater with high concentration of toxic metals. In this context, this research aimed the copper recovery optimization and the production of NiCu alloy from an...
Ver mais
Abstract: The recovery of metals from wastewater is a recurrent a problem due to large number of manufacturing process that generate wastewater with high concentration of toxic metals. In this context, this research aimed the copper recovery optimization and the production of NiCu alloy from an industrial wastewater and using pulsed electrodeposition. Therefore, the pulsed chronoamperometry was used as the deposition method with the evaluation of the current applied, the electrolytic bath temperature and the cathod rotation. The process to produce the metallic copper showed 33.59 % of copper removal with a deposition efficiency of 84.36 % in 30 minutes, using fast pulsed chronoamperometry, ton= 1ms, 190 mA, 70 rpm and 37 °C. The kinetic study of this process allowed a higher removal percentage, of 82.49 % at 37 °C with 115 min of reaction. The results pointed that in the temperature range from 20 °C to 40 °C the process can be described by the pseudo first order model, based on an irreversible reaction. With the change of the parameters studied it was possible to remove copper with production of crystalline oxides up to crystalline copper in its metallic form. Experiments conducted at 10 °C and 50 °C indicated that the parallel reaction of copper I oxide formation is favored at these temperatures. The experiments to obtain the NiCu coatings indicated the optimized parameters to produce a homogeneous material, nanocrystalline, with composition similar to the commercial monel alloy and with elevated corrosion resistance in NaCl 3.5 %. The optimized parameters were pH 9, 0.200 mol/L of Ni+2, 600 mA, ton= 1ms, 20 rpm, 40 °C on copper substrate. This research indicated the significant influence of the nickel concentration, the electrical deposition current and the cathod rotation on the deposition efficiency and the metallic alloy composition, emphasizing the importance of low rotation to obtain coatings with higher nickel concentration and homogeneous, increasing the corrosion resistance. With the evaluation of the mechanisms used, we concluded that the fast pulsed chronoamperometry as electrodeposition technique for the reduction of metallic ions in solutions is feasible and presented great potential to remove and reuse metals coming from wastewater
Ver menos
Requisitos do sistema: Software para leitura de arquivo em PDF
Almeida Neto, Ambrósio Florêncio de, 1979-
Orientador
Vieira, Melissa Gurgel Adeodato, 1979-
Coorientador
Rabelo, Ana Paula Brescancini
Avaliador
Doubek, Gustavo, 1984-
Avaliador
Maciel, Maria Regina Wolf, 1955-
Avaliador
Eletrodeposição pulsada para a remoção e reúso do cobre de efluentes industriais e a formação de revestimentos de NiCu resistentes à corrosão [recurso eletrônico] = Pulsed electrodeposition for the removal and reuse of copper from industrial wastewater with produciton of NiCu corrosion resistant coating
Thayane Carpanedo de Morais Nepel
Eletrodeposição pulsada para a remoção e reúso do cobre de efluentes industriais e a formação de revestimentos de NiCu resistentes à corrosão [recurso eletrônico] = Pulsed electrodeposition for the removal and reuse of copper from industrial wastewater with produciton of NiCu corrosion resistant coating
Thayane Carpanedo de Morais Nepel